Your Price Offer List

Buckling Test

It is conducted for checking out the buckling resistance of the centre rods produced. It is a statically applied test. Load is increased by starting half force of buckling force calculated gradually up to 20% more of the buckling force calculated. At the end of the test, it is necessary for a part not to subject to any plastic deformation. Tests up to 120 kN calculated can be carried out on the products.